GRID SYSTEM OPERATION SUMMARY (SABAH)

FORECAST ACTUAL VARIANCE

Maximum Demand (27th JAN' 2013) 720 MW 711 MW ‐1.19%

Maximum  Energy (27th JAN 2013)       14.9 MW 13.6 GWh ‐8.72%

Maximum Demand (record high 28/06/11) 800 MW 830 MW 3.76%

Prepared by:

Electricity Market Operations

Electricity Supply & Market Regulations Dept. y g p Energy Commission Malaysia

22‐Feb‐13

(2)

OPERATION

500MW EAST COAST GRID GENERATION PROFILE ON 27th JAN' 2013

‐200

‐100 0 100 200 300 400 500

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 HOUR

INSTALLED CAPACITY ON LINE CAPACITY

DEMAND OPERATING RESERVE

37853.3 37395.5 36612.3 35636.9 34937 35757.7 32655.8 33873.8 35502.9 37288.5 38239.4 38106.6 38095 38189.2 38061.8 37702 37168.9 35493 42589.8 43032.2 42645.8 38834.5 39208.6 38272.6

WEST COAST GRID OPERATION West Cost

h '

EAST COAST GRID

INSTALLED CAPACITY 417.9 417.9 417.9 417.9 417.9 417.9 417.9 417.9 417.9 417.9 417.9 417.9 417.9 417.9 417.9 417.9 417.9 417.9 417.9 417.9 417.9 417.9 417.9 417.9

ON LINE CAPACITY 96 62 62 62 62 62 62 65 65 92 107 107 107 107 107 107 117 216 230.5 230.5 221.5 216 123 84

DEMAND 205.67 200.21 194.68 190.55 186.61 192.8 171.56 181.06 193.2 202.04 206.54 201.72 202.81 201.38 202.85 200.27 200.3 223.86 250.39 252.82 248.1 240.5 217.57 203.78 OPERATING RESERVE -109.67 -138.21 -132.68 -128.55 -124.61 -130.8 -109.56 -116.06 -128.2 -110.04 -99.54 -94.72 -95.81 -94.38 -95.85 -93.27 -83.3 -7.86 -19.89 -22.32 -26.6 -24.5 -94.57 -119.78

East Cost 11524.3 8042.28 8049.51 7976.28 8121.65 8104.73 8159.72 8213.56 7901.59 10051.4 11384.8 11210.4 11248.1 11303 11021.8 11962.1 13694.3 22704 26788.9 26738.9 24916.9 23579.2 14645.1 11116.9

EAST COAST GRID

WEST COAST GRID

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

INSTALLED CAPACITY 858.5 858.5 858.5 858.5 858.5 858.5 858.5 858.5 858.5 858.5 858.5 858.5 858.5 858.5 858.5 858.5 858.5 858.5 858.5 858.5 858.5 858.5 858.5 858.5 ON LINE CAPACITY 582.5 582.5 582.5 582.5 582.5 582.5 582.5 582.5 604.5 604.5 609 609 609 609 617.5 617.5 617.5 617.5 658.5 658.5 658.5 617.5 617.5 617.5 DEMAND 493.5 485.8 470.7 458 448.3 459.2 416.9 429.4 469.6 496.5 503.5 502.2 501.7 507 499 491.3 482.9 460.2 529.5 537.8 539.3 514.5 518.6 504.6 OPERATING RESERVE 89 96.7 111.8 124.5 134.2 123.3 165.6 153.1 134.9 108 105.5 106.8 107.3 102 118.5 126.2 134.6 157.3 129 120.7 119.2 103 98.9 112.9

0 100 200 300 400 500 600 700 800 900 1000

10 11 12 13 14 15 16 17 18 19 20 21 22 23 24  MW

HOUR WEST COAST GRID GENERATION PROFILE ON 27th JAN' 2013

INSTALLED CAPACITY ON LINE CAPACITY

DEMAND OPERATING RESERVE

DEMAND OPERATING RESERVE

(3)

Daily Generation Mix Profile for 27th JAN' 2013

71.0%

10.5%

14.4%

4.1%

Gas

Hydro

Distillate

SREP

BIOMASS

30%

70%

Generation Mix Profile for 27th January 2013

Gas              9,868 MWh

Hydro              1,460 MWh Distillate              2,005 MWh

SREP                 571 MWh

DISTILLATE GAS HYDRO

SESB           688.3 5 MWh        2 ,409.70 MWh      1 ,344.00 MWh        ‐ MWh

IPP       1 ,317.10 MWh        7 ,458.00 MWh          115. 80 MWh        ‐ MWh

SREP                  ‐ MWh               ‐ MWh        ‐ MWh        570.60 MWh GENERATION MIX SESB‐IPP‐SREP 27th JAN' 2013

TOTAL       2 ,005.45 MWh        9,8 67.70 MWh      1 ,459.80 MWh        570.60 MWh

DISTILLATE GAS HYDRO BIOMASS

SESB 5% 17% 10% 0%

60% 54%

IPP 9% 54% 1% 0%

50%

SREP 0% 0% 0% 4%

TOTAL 100% 100% 100% 100%

40%

TOTALLY     13,903.55

DIST (IPP) 9%

DIST (SESB) 5%

SREP 4%

GAS (SESB) 17%

GAS (IPP) 54%

HYDRO (SESB) 10%

HYDRO (IPP) 1%

total 100%

0%

10%

20%

30%

SESB IPP SREP

5%

9%

0%

17%

0%

10%

1% 0%

0% 0% 4%

DISTILLATE GAS HYDRO BIOMASS

Referensi

Dokumen terkait

When the islanding switch disconnects the main grid from the local load, the DG will supply the local load with the same value of the voltage magnitude, current, active and

SANDBOXES  an environment where the program can execute but can’t affect the rest of

This thesis is the final academic requirement of students of International Undergraduate Program to graduate and obtain the bachelor degree. We are very proud of the hard work we

We design and implement Service Oriented Distributed Grid Manager SODGM framework based on web services technology to manage resources and jobs in the system.. SODGM balance the load

The integration of wind generator along PV cell and battery system will enhance the quality of power and the extra active power will result in boosting up of voltage.. This has its own

the currently competitive small generation units and the incentive laws to use renewable energies force electric utility companies to construct an increasing number of distributed

HARDWARE AND SOFTWARE REQUIREMENT The power supply unit, microcontroller, utility grid, Solar PV system, relay unit, load, and IOT make up the uninterrupted micro grid power management