DESIGN AND ANALYSIS OF MONITORING COS PHI VIA WIRELESS

Name : Nadira Register Number : 3204161067

Supervisor : Johny Custer, ST., MT

ABSTRACT

Currently, electrical energy has become one of the primary human needs in all environments, be it at home, work place or factory. For this reason, it is necessary to monitor cos phi via wireless, electric power so that electricity consumption can be monitored easily and to find out about excessive usage out of the ordinary, in our research we used a cos phi monitoring system on the load of fans, irons, rice cookers and lights. Control system through visual basic display on laptop/PC. In this research, the system being developed is based on Arduino Nano. In controlling, this system uses the NRF24L01 module to monitor cos phi while the sensor used is the HLW8012 sensor. The result of the comparison of data per hour is that at a distance of 50 meters the average cos phi 0,06, the average voltage is 16 volts, the average current is 0,59 amperes and the average power is 161 watts, while at a distance of 100 meters the average-average cos phi 0,02, average voltage 16 volts, average current 0,51 and average power 160 watts. This proves that there are differences in data using different mileage. The maximum distance that the NRF24L01 can cover is 115 meters, if it exceeds that, the data sent will not be read on the monitor display or the visual basic display.

Keywords: Arduino Nano, Sensor HLW8012, NRF24L01.

Referensi

Dokumen terkait

To construct the vehicle body with fiberglass, there are several techniques can be used and Hand layup techniques is one of the famous technique that widely used due to it

Graphical user interface (GUI) is created and developed by using Visual Basic 2008 as internal controller and monitoring system and the signal from machine

4.1 The working hour per day of worker 51 4.2 Duration time for worker used the wheelbarrow 52 4.3 To measure how frequent the worker used the wheelbarrow per day 53 4.4 The list

The measurement data of monitoring and tracking with dynamic model shows the average interval value, avarage deviation and the smallest average delay value, is

So in a day of electrical power that can be used for charging the battery is 10 amperes x 9 hours = 90 amps so the electrical power produced is 3 As long it takes to charge the

1.2 GENERAL REMARKS ON THE ANALYSIS OF INCOMPLETE BLOCK DESIGNS The analysis of incomplete block designs is different from the analysis of com- plete block designs in that comparisons

The purpose of the research to be achieved in this study is to develop a student academic monitoring information system that is in accordance with the needs of SMAN 9 Balikpapan, saves

The depth of bedrock in the research area varies from 20-40 meters, the thickness of topsoil is dominated in the value range of 3.6-5 meters, while the thickness of the laterite