ABSTRACT

Lightning strike is the major factor that leads to overvoltage and equipment failure in

electrical power system. Thus, insulation coordination is an essential part of power system

studies and was used to detennine the performance of a transmission line or substation.

This project generalizes the modelling of 132kV transmission line design for the purpose

of backflashover simulation using the power system simulation tools that is Power System

Computer Aided Design (PSCAD) software. Sample of transmission line data was taken

from Tenaga National Berhad (TNB) for the purpose of simulation using PSCAD software

.Crucial part of the studies include the model of transmission line components such as

insulator coordination, tower model, tower footing model and surge arrester. This research

will focus on the effect of different position of transmission line surge arrester placement at

transmission line to the value of backflashover rate. A model of surge arrester is

implemented in PSCAD simulation across the line insulation, to prevent flashover. The

capabilities of arrester are investigated so that the proper arrester rating can be selected for any system requirement. In addition, extensive analysis on the placement of surge arrester

at the substation and the prediction of probability of transformer damage are also

presented. Results were analyzed and the influence of transmission line surge arrester

placement to backflashover rate at transmission line and the probability of transformer

damage at substation were discussed. The results will be discussed based on literature

review and previous findings obtained by other researchers. Findings from this project can

be a significant modelling guideline to the transmission line designers or other researchers

to improve the performance of overhead transmission line in term of backflashover rate

and probability of transformer damage at substation.

(8)
(9)
(10)
(11)
(12)
(13)
(14)
(15)
(16)
(17)
(18)
(19)
(20)
(21)
(22)
(23)
(24)

Referensi

Dokumen terkait

a) Analysis is on the transmission line 275kV double circuits. b) The specification of tower 275 kV is taken from Tenaga Nasional Berhad Transmission, Malaysia. c)

ground wire has been located at the transmission line to minimize the number of lightning.. strike that terminates on the phase conductor, the backflashover still can occur and

* Corresponding author : [email protected] Human error probability analysis of overhead crane operation in steel fabrication company using SLIM-DEMATEL-ANP method Annisya

1.4 Research Hypothesis “The finite element analysis based model can be developed to predict the self-damping properties and behaviour of overhead power line conductors subjected to

©Daffodil International University 36 CHAPTER 5 Distribution of Substation 5.1 Distribution Transformer A distribution transformer or service transformer could be an electrical

CERTIFICATION OF APPROVAL Design of Transmission Line Tower and Its Performance Approved by, by Mohd Shafiq Bin Mohd Zulkifli 10778 A project dissertation submitted to the

This paper presents a mitigation plan for lightning strikes towards the transmission line tower at Kedah Paddy

In this paper we will describe shortly transmission lines, scattering parameters, quarter-wave transformer and at the end we have analyzed one example regarding to line matching using