• Tidak ada hasil yang ditemukan

Index of /enm/images/dokumen

N/A
N/A
Protected

Academic year: 2017

Membagikan "Index of /enm/images/dokumen"

Copied!
5
0
0

Teks penuh

(1)

EASTERN CABIJS LTD. North Patene3. Chltl.rqon!

-: lntlmttioonl Tcndcl Nodcc: _

rnwer

ftmrl

e

Qi&

q-dstl{ltu' {tan tfr{ cr<'r{rr{dE vrc)

s..!"-

c$r*

Ltc,

p"i;";;;*c"s

tt"ii"

"*l"a "'a€r with l% Bmcct Monev for Focurment utrder m€dlotred i!.m on C&F (C) Chittagong basisr

NB: '

'-'

(|)

." il:

ltem No: I - ) lrcm No: I - CoPp€f wirli - P.iC€ will be balad otr LMB derag!-scttlem'Dt Plicc ofcoPparclEde

"ruii.Lj

i. rra",a edbd; i_ondon-ior rho month prior to rhc

monih of shipment plus pr.Eium, 8ei8ht and

r"."ia"""t Cttlmi."io"

ttrag

C&F (c) Chittsgolg lhcr teln basi!'

ffiil'#;;;;n;l'ff'tr"

a,itis *otti'giours on clsh pavmcot (Dotr-refiDdablc) tod fte followins olfices:

-l.

Cas[ SectioD, Easl.m Cables Ltd , Paterya" Cbittagolg'

i.

i*l

s""t*,

sssc Bhsbar\ I02- tkzi Nazul lsllm Avonuc' Dhakr-1215' No rcncler doclJocdt3 will be 3old on ttc oPmjtg d!!o oftendcr'

/

n

V&''

(Mohrmm.d Shrliqul IslaD)

Head of Puchase DepartBe[t For Malaging Dir€ctor.

st Op.oltr8dtt.

TK.1,000.00 At 27.10.201012.05 PM Ar 3.05 PM30.r0t010

01. EC|?URIT.5l5dl.02.lo.?010 Siz!: E da

Ontv: 200 M.T

27,t0.20r0 At 12.05 PM

30.10.2010 At 3.05 PM oz. EC,"UR/F-5I9dr 02.1o2010 P.V.C Rlstn Ttc 500,00

TIC 200.00 At 27.t020t0t2.05 PM Ar 3'ol0.2Oro!.05 PM

01. E0PUXTT-516dr.02.10.2010

ACSRcorc wrt ro. tmKls ACS Doa

Siz.:7x 1.5? mm Qntv: 50 ll'T

04, EC/rdR/F-517dr

02.10.2010

ACSR Cor wirc for dtldnS ACS MBliti Si4: rx 3 47 tun

ontv: 75 M.T

TK.200.00 Ar 27.t0.201012.05 PM Ar 3.05 PM30.10.2010

05. Bc,"lrx,|F-518dr 02,102010

Solcl Sttips

Siz!: I6x05tm

Ontv: 5 M,T

TX- 200.00 Aa 12.05 27.10.2010PM 413.05 30.10.2010PM

(2)

Annexurg -

I

SPECTTTCATION OF STEEL

CORI

WIRE FOR ACSR

.MERr/lN'

SIZ,E:

I

x 3.47

mu.

dia.

Ouantity: 75 M.

.f.

SPEcIFICATION

r

Galvanized steel core wirc for

ACSR'MERLIN'

complying to tlrc specfication of ASTM

B

498-74 (1979) of class

'A'

coating and latest revision drereof. The ooye wire

will

be used to manufacture ACSR conductor as per ASTM B 232

-86 & latest revision thcreof.

SAM|L&:

A sample of 5 meter,

ifnot

carlier used tested by ECL for acceplanca, must be submitted with the offer.

EAg5Ug:

Thc steel core wirc to be supplied in single length

of

10.20 km per wooden reel. The wooden reel must be sturdy treated, wrapped

with

polythene paper

of

suitrable rust & moisturo protection. The steel core ]virc shall be pmvided by use of a suitable corrosion

ifibitator

grease or oil.

The dimension ofwooden reels are as follows :

-Flange dia Bore dia

Flange thickness Banel dia

Overall width

860 mm 80 mm 60 mm

(350

-

400) mm 545 mm

The bidd€r's

shlll

have to submit the following documetrts

at

the time

of

submission of ouotation:

l.

Full technical Specification & details.

2,

Technicalliterature.

3.

Miil

test Certificate.
(3)

Annexnre -

I

SPECEFICATION

OF' COPPER

WIRE.

OIJATTIIItr.2!XT.I4J,

Continuous Cast Hot Rolled Pickled & Annealed Electrolytic Copper Wire 8 nun Dia meter for production ofElectric Cablos

&

Wire (ASTM 849

-

78;

ISC

3102) or any convenient diameter.

Diameter

Tensile Strength Elongation

Conductivity at 200 C

Sp. Gravity Pudty

8.00 mm (Tolerancr

I

0.38 mml or any convenient diameter.

25 Kg/mm' (Max)

35% (Min)

100% of IACS (Min)

8.90;

99.90 % (Min).

The surface of Wire shall be wax coatcd, bright and completely free any black stain. The Wire shall be fre€ ofimperfection not consistent with good conunercial practic€,

After drawing the Wire shall satisry the reqriirements

of

JISC

-

3102

for

annealed Wire and JISC

-

3 I 0

|

for un annealed (hard drawn) Wirc.

Packing:

The material shall be supplied in compactjumbo coils of2500 kgs incase of 8 mm diameter and packing method for other diametcr to bo

mentioned by the bidders.

Sample:

A

sample

of

100-meter lenglh must be supplied

with

the offer,

if

the

material has

not

been earlier used

or

tested

for

acceptance

by

ECL.

The bidder's sball

have

to

submit

th€

following

documents

at

the time of

submigsion of quotationr

1,

Full tecbnical Sp€cificrtlon

&

details.

2.

Technicalliterature.

3,

Mill

Test

Certiliclte.

4.

M8nufrcturer's

Certificate conlirming the tender Spccilication.

5.

Informltion

about supply records for

lrst

thre€ years.
(4)

Atrnexur€ -

I

SPECIFICATION

OT'

STEEL

STRIPS

SIZE

r

l6x0.5mm.

Quantity

:5M.Tons

Sp€cification: Eloctro galvaniz€d cold rolled mild st€.I

stips

sonealed asd re-mlled, teosile

tlttgth

4-3 kgimm' (M.x.) accordbg to JIS C-3313 in a single length coil vdth edges lotary

sheaved a.fler galvanizing Coils to have an inside dia. of300 rnm. snd an outside diia" should not bc less than 5@ mm. aod should not cxcecd 600 It|I!r. Toleranc€ to DIN l5!t4, wrap!,cd with suitrble means for rust and moistwe proteotion. Electro galvqnized zinc coating 35 gmltrP minimum, with bright surfacc Aee ff,om any rust and scmtch.

PACKING I

Material should be supplied in standard export qualig packina suong enough to withstaid rcugh handliDg during ftmsportation.

The bidder's

shall

have

to

submit the

fo

owing

documents

at

the

time

of

submission of

ouotation!

1.

Full technical Specifrcation

&

details.

2.

Catalogues/Technicalliterature.

3.

Manufacturer's Certificate confirming the tender

Specification-4.

Information about supply records for last thr€e years.

6/8

(5)

Annexuft - I

Ourrtitv: 60 M.T. STRAND NO: Of wi.es x dianeter in mm = 7 x L57

SPECIFICATION:

Galvgnized steel core wire ofstrardcd corc shall satisfy the requircmcnts ofthc specificatiol of

83-4565: 1970; BS

-

443: 1982 dnd laresr revision tfrelcoe

ni

suanal

*ro

*ii

irr u

"""a

lo Danufacturc ACSR .DOC' conductor as Dca BS _ 215

(Part

-

n) 1970 and tatest revision rhereof. ihc ray factor ofthc

stccl wirc shall bc not less

tt'n

13 and not mor€ than 20 times thc out sidc diarnctir ofthe strandJ eo* .,ritf, tfr"l"v'L f"n fralla

dircction- The stcel corE wire shan b€ provided by u"e

.f

suirabi;;;;;i;;

;;iil#;;;

oil

NOTE: Negative toleBnce of diameter of steel core wirc will not bc acceptablc.

SAMPLE!

5 (Five) mcter must be s.pplied aroog with the off6r ifthe maierisl is not earrier

usedtasied by Eastcm Clblcs Ltd.

PACKING:

The sb-anded stel corc wire to bc supplied in siDgte lenSth ofg.5 Ien +

lyo in wooder Drurn. 11:

:-o"n.

,ryr

..lst

bc sturdy tr€ated., wrapped with polythenc psFr of suitrbte rust & moisture prol@tion insidc the woodcn packrng.

Tbc dimension ofwoodcn Drums are as follows'l "

Flange dia BoIe dia

Flange thickness Bancl dia Oveall wid0r

1000 mm

80 mm

55 mm

400

-

500 mm

660 mm

Thc bidder'! shrlt have to submlt the followitrg do.uDeot,

it

tbe

tl'|e

of lubmis3ior of quotellor!:

l.

Futl technical Specification & details.

2.

Technicallilerature.

3.

Mill t st Certificatc.

4-,

Manufacturer's Certificil€ confirming the tender Speoificstion,

Ell0{8{8 DL\D..wiD! .rd S.nintrUohoD\pUiCH SE Dtp RTMENT[tpc.ifiurih\5IECInCATION Op ?VC R!sll{,.{toc

Referensi

Dokumen terkait

[r]

Tujuan komunikasi yang terdapat di dalam perancangan identitas dari Situs Taman Purbakala Cipari ini adalah menciptakan suatu identitas berupa logo yang memiliki ciri khas dan

berdasarkan hasil uji ANOVA dengan signifikansi 0.000 (p&lt;0.01); (2) pembelajaran menggunakan model Problem-Based Learning berpengaruh terhadap penguasaan konsep

Sasaran yang dituju dalam proses komunikasi massa adalah khalayak atau masyarakat luas yang terpencar satu sama lain tidak saling mengenal, karena masing – masing berbeda

Walaupun patogenesis dan penyebab yang dicurigai telah ditemukan, ternyata pengobatan yang diberikan kadang-kadang tidak memberikan hasil seperti yang diharapkan.Urtikaria atau

tersebut, karena merupakan pesan atau solusi yang diperpendek menjadi sebuah kata-kata yang mudah dimengerti, serta dapat memotivasi pendengar, penyiar berusaha

Terapi obat dan tindakan pembedahan dapat digunakan untuk mengecilkan atau menghilangkan miom jika menyebabkan rasa tidak nyaman atau gejala-gejala yang bermasalah..

sanggahan selama 3 (1iga) hari kerja dari langgal 16 Sid 18 Juni 2015, yang dilujukan kepada Uni1. Layanan Pengadaan Kementerian